22
CRYSTALVIEW PLUS INSTALLATION AND OPERATIONS MANUAL
Reset keyboard and mouse[F1]
Pressing the [F1] key while in the command mode will reset the keyboard
and mouse, and then exit the command mode. Use this command if the
keyboard or mouse lock up or the mouse does not initialize properly.
Send NULL mouse byte[F3]
Pressing the [F3] key while in the command mode will send a NULL byte to
the system and then exits the command mode. Use this command to re-
synchronize an out of sync mouse. This command may need to be issued
several times to re-sync the mouse.
Reset to factory defaults [L-Ctrl] + [F9]
The reset to factory default command will reset the HF and LF equalization
values, all color delay values and all configurations for all channels back to
the original factory defaults and then exit the command mode.
Toggle Unit Private Mode [Scroll Lock]
CrystalView Plus models with local KVM access have a private mode
available which can inhibit the local or remote unit. When the local or
remote unit issues this command, it blanks the monitor and prevents the
other unit from being used until the private mode command is issued again.
To indicate that a unit is in the private mode, the scroll lock LED will slowly
flash. To cancel the private mode, enter the Command Mode and press the
Scroll Lock key again.
Local unit Keyboard commands (Dual local model only)
To initiate a local unit keyboard command, first press the “HOT-KEY” then
the command. The default “HOT-KEY” is the right control key. To change
the default “HOT-KEY” from the right control key to the left control key, enter
the Command mode and press [F7]. This toggles the “HOT-KEY” from the
right control key to the left control key. When the [F7] key is pressed, the
“HOT-KEY” change is saved and the unit exits the Command mode and
returns to normal operation.
The local user can start a private session by pressing the “HOT-KEY” (right
control key), then the scroll lock key. When the local unit is in the private
mode, the Scroll Lock LED on the local unit flashes and all three LEDs on
the remote unit will illuminate. The remote monitor is blanked and the
keyboard and mouse are disabled.
Reset the local keyboard and mouse
If the local keyboard or mouse locks up, you can reset them by issuing the
reset command. Press the “HOT-KEY”, then [Num Pad Left Arrow]
(generally the “4” key on the numeric keypad)